The purpose of the 2008K Hemodialysis Machine Operator’s Manual is to instruct qualified patient-care staff in the function, operation, and maintenance of the 2008K hemodialysis machine. Fresenius Medical Care, the world’s largest provider of dialysis products and services, has won the Red Dot Award: Product Design for the company’s 6008 CAREset. This advanced all-in-one disposable with pre-connected bloodlines combines with the 6008 dialysis machine to form the 6008 CAREsystem.
*Fresenius 2008
*Fresenius 2008k Spare Parts Manual
*Fresenius 2008t Dialysis Machine Manual
*Fresenius 2008 Dialysis Machine Manual MachineI’m having a problem with a 2008K machine in regards to ’high’ TMP (technically low because TMP is a negative measurement). It does not go high enough to alarm, but it runs around 360-420 during a normal treatment and while in the technical office during troubleshooting. This is without the UF pump turned on. I have verified all calibrations numerous times. I have tried swapping in a whole card cage including cables to rule out electronics, which resulted in the problem following the hydraulics, so I know it’s not any of the boards (except maybe the distribution board). I have tried swapping the entire balancing chamber (including valves)and hydroblock with known good ones. I have tried bypassing the heat exchanger, tried a new pressure transducer, verified the pump calibrations/incoming water pressure/dialysate pressure/venous pressure/flow, dear, and loading pressures/ all numerous times, even recently and all are good. I have replaced the CFS switch and the entire air separator assembly (valve 43 included) with new parts to rule those out. At this point I’m at a complete loss. As a side note, I have tried using the troubleshooting guide. Unless you have a problem that causes an alarm state (which I don’t, just TMP running higher than it normally should) the guide is next to useless.I’ve started heading in the direction of a restriction from a valve starting with bypassing valve 25. I’m looking for some ideas here. Help!!! ;-)
Fresenius Medical Care (NYSE:FMS) said today that it launched its 2008T BlueStar hemodialysis machine, touting more than 30 improvements from previous device models.
The Waltham, Mass.-based company said that the new system is intended to allow for simpler operation and maintenance with additional treatment options, and added that the system features a number of newly automated technologies.Fresenius 2008
“The new and enhanced 2008T BlueStar hemodialysis machines provide more than 30 unique enhancements to better serve end stage renal disease patients undergoing dialysis. Our new machines represent a significant step forward for providers and patients who depend upon our life-sustaining technologies and an exciting continuation of our 30-year commitment to the treatment of end stage renal disease,” Fresenius Medical Care NA renal therapies group prez Mark Costanzo said in a prepared statement.
The newly launched dialysis system features auto-start and auto-prime features, as well as assisted reinfusion, Fresenius Medical Care said. The device also features an idle mode to reduce dialysate and water usage, independent conductivity and pH self-testing, a disinfection log, patient cards and low volume therapy treatment capabilities.Fresenius 2008k Spare Parts ManualFresenius 2008t Dialysis Machine Manual
“Leveraging our history of innovation and industry firsts in renal care, we are pleased to unveil new features that will help providers deliver the highest quality of care to patients receiving hemodialysis both in-center and in the acute care setting. We believe our 2008T BlueStar machine offers distinct clinical advantages that streamline the complexities of hemodialysis care and enhance patients’ overall treatment experience,” Fresenius Medical Care NA renal therapies group chief medical officer Dr. Robert Kossmann said in a press release.Fresenius 2008 Dialysis Machine Manual Machine
In late January, Fresenius said that an interruption to the FTC’s review of its merger with NxStage Medical (NSDQ:NXTM), caused by the partial U.S. government shutdown, has again delayed the end-date of the deal which has now been extended to August 6, 2019.